☰
Current Page
Main Menu
Home
Home
Editing 2_Installation Instructions Revised
Edit
Preview
H1
H2
H3
default
Set your preferred keybinding
default
vim
emacs
markdown
Set this page's format to
AsciiDoc
Creole
Markdown
MediaWiki
Org-mode
Plain Text
RDoc
Textile
Rendering unavailable for
BibTeX
Pod
reStructuredText
Help 1
Help 1
Help 1
Help 2
Help 3
Help 4
Help 5
Help 6
Help 7
Help 8
Autosaved text is available. Click the button to restore it.
Restore Text
> {width="1.5520833333333333in" > height="1.4993055555555554in"} > > **[INSTALLATION]{.underline}** Select the desired location for the remote switch panel, preferably inside the boat. Make sure the location gives you access for running all your wires and that it is close to the 12-volt DC power source. Note: *All installation is to be done [before]{.underline} power is applied to the control box by inserting the fuse.* {width="2.109722222222222in" height="1.6666666666666667in"}Use a template to make the cutout in the selected location and cut the hole with a jigsaw. It is recommended that you protect the surface of the cutout area with tape to avoid scratching the surrounding surface. - 3 Gang Switch - Template should be 3" by 1-5/8" - 5 Gang Switch - Template should be 5" by 1-5/8" - 6 Gang Switch - Template should be 6-1/8" by 1-5/8" ```{=html} <!-- --> ``` - {width="2.060416666666667in" height="2.329861111111111in"}**[Make sure you have additional room for the face plate of the panel before cutting.]{.mark}** Install switch panel into cutout, predrill pilot hole and screw in place with #6 pan head screws. Mount the command box in a desired location close to the breaker panel or other power supply terminal and within 3' from the desired switch panel location so that the switch harness will reach the switches. (note: additional 3 foot harness are available and can be connected together to increase length. The harness wires may also be spliced with 18-gauge wire for a distance up to 40 feet) {width="1.7673611111111112in" height="1.9569444444444444in"} Install wiring for the lights, siren, P.I.R. motion sensor, and power according to the wire labels (use your best judgment and always use wiring glands when drilling through watertight membranes). *Pirate Lights Marine Security \| **Installation** page 1 of 2* [Please see attach wire size chart for recommended wire gauges used for different configurations.]{.mark} - *DC current is susceptible to voltage drop over wire distance and therefore must be sized for the distance and power needed on each wire run (please use the attached reference table to determine the recommended wire size for the number and size of lights for your application).* **[Note]{.underline}**: There is one 16ga / 3 conduit wire labeled "RGB Light Bar" -- the system can directly power a total of two 12" light bars [OR]{.underline} one 20" light bar through this wire. *If you desire more lights, we can create a custom set up to add as many lights as you would like by using waterproof relay. Please contact us for more information or to discuss other lighting options.* {width="1.3125in" height="1.3958333333333333in"} Terminate lights, siren, motion sensor(s), beam break sensors, float switch, and smoke detectors with heat shrinkable butt connectors. {width="3.102777777777778in" height="2.8805555555555555in"} Terminate lights, siren, motion sensor(s), beam break sensors, float switch, smoke detectors and power with the command box and attach them appropriately to the labeled wiring and wire flow chart provided. The final termination is at your 12-volt DC power source, install a 15A fuse holder or attach to a 15A circuit breaker. **It is extremely important to terminate the wiring with all connections per the wire labels.** {width="1.6972211286089238in" height="1.6391010498687664in"} > ***If you have any questions, please contact Pirate Lights.*** > > {width="0.5116272965879265in" > height="0.5116272965879265in"}***Donald (Product Engineer)\ > *** > > ***WhatsApp# : (904) 552-5886\ > email : Sales@PirateLights.com*** > > ***Please leave a message if we don't answer immediately.*** ***\ **Pirate Lights Marine Security \| **Installation** page 2 of 2* **[Wire recommendations:]{.underline}** **[For all Sensors & Siren:]{.underline}** (Motion Sensor, Float Sensor, Beam Break Sensor, Smoke/Heat Detector) - We recommend using a good, **[SHIELDED]{.mark}** 22AWG stranded copper core 4 conduit alarm wire for all the sensor installation along with a Type B waterproof connector with sealant. - Although you will not use all four wires, it is round, PVC insolated, cost effective, and has its length labeled every foot for easy installation. - This can be used for the Siren(s) as well (*out to 42' of cable length*) and can be bundled together (*two wires for power and two wires for ground*) for using two sirens on the same length of cable. {width="1.2944444444444445in" height="1.4076388888888889in"} {width="2.8055555555555554in" height="1.073611111111111in"}{width="2.7481649168853894in" height="0.7013888888888888in"} {width="2.183333333333333in" height="0.89375in"} **[\ For Blind Light(s):]{.underline}** {width="4.188888888888889in" height="0.9340277777777778in"}We recommend using a 16 AWG 2 conduit tinned copper marine wire. {width="2.594232283464567in" height="1.3777602799650044in"} **[For the RGB Light Bar(s):]{.underline}** {width="4.313432852143482in" height="0.9006496062992126in"}We recommend using a 14 AWG **[[3]{.underline} conduit]{.mark}** tinned copper marine wire. [PLEASE NOTE THAT THERE ARE **[3 (THREE)]{.underline}** WIRES REQUIRED FOR THE RGB LIGHT BARS]{.mark} **[For the System Power Supply:]{.underline}** {width="4.268055555555556in" height="0.9208125546806649in"}We recommend using a 12 AWG 2 conduit tinned copper marine wire and a 12AWG inline fuse. {width="2.313888888888889in" height="0.8611111111111112in"} *\ Pirate Lights Marine Security \| **Max Wire Length For Wire Gauge Size** page 1 of 2* +-----------------------------------------------------------------------+ | [Max Wire Length For Components & Wire Gauge Size]{.underline} | | | | [\ | | ]{.underline} | | | | ----- | | --------------------------------------------------------------------- | | --------------------------------------------------------------------- | | | | **Per Individual Wire Run** | | **22 **20 **18 **16 **14 **12 | | | | | | Gauge** Gauge** Gauge** Gauge** Gauge** Gauge** | | ----- | | --------------------------------------------------------------------- | | --------- --------- --------- --------- --------- --------- --------- | | {width="0.71875in" height="0.23125in"}One 12\" RGB | | Light Bar x x 46 Feet 73 Feet 117 Feet 186 Feet | | | | ![] | | (media/image28.png){width="0.71875in" | | x x 24 Feet 38 Feet 61 Feet 97 Feet | | height="0.23125in"}{width="0.71875in" heigh | | t="0.23125in"}Two | | 12\" RGB Light Bars | | | | | | {width="1.5104166666666667in" | | x x 27 Feet 43 Feet 69 Feet 111 Feet | | height="0.25277777777777777in"}One 20\" RGB Light Bar | | | | | | {width="0.7321434820647419in" | | | | height="0.29985454943132106in"}Blind Light | | | | | | {width="0.7321434820647419in" | | | | height="0.29985454943132106in"}{width="0.732143482064 | | 7419in" | | height="0.29985454943132106in"}Two Blind Lights | | | | | | {width="0.3854166666666667in" | | 42 Feet 67 Feet 107 Feet 170 Feet 271 Feet 431 Feet | | height="0.4479166666666667in"}One Siren | | | | | | {width="0.3854166666666667in" | | 22 Feet 36 Feet 57 Feet 91 Feet 146 Feet 232 Feet | | height="0.4479166666666667in"}{width="0.385 | | 4166666666667in" | | height="0.4479166666666667in"}Two Sirens | | | | | | {width="0.36180555555555555in" | | 125 Feet \- \- \- \- \- | | height="0.7909722222222222in"}PIR Dual Tec | | | | | | {width="0.3854166666666667in" | | | | height="0.4583333333333333in"}{width="0.4875in" | | | | height="0.4895833333333333in"}Up to 5 Beam Breaks | | | | | | {width="0.38300306211723534in" | | | | height="0.4554625984251969in"}{width="0.4875in" | | | | height="0.4895833333333333in"}Up to 10 Beam Breaks | | | | | | {width="1.1368055555555556in" | | 350 Feet 550 Feet \- \- \- \- | | height="0.42291666666666666in"}Float Switch | | | | | | {width="0.5621270778652668in" | | | | height="0.5382064741907262in"}Up to 3 Smoke Detectors (longest ru | | n) | | | | {width="0.5618055555555556in" height | | ="0.5375in"}Up to | | 5 Smoke Detectors (longest run) | | | | ----- | | --------------------------------------------------------------------- | | --------------------------------------------------------------------- | +=======================================================================+ +-----------------------------------------------------------------------+ *Pirate Lights Marine Security \| **Max Wire Length For Wire Gauge Size** page 2 of 2*
Uploading file...
Edit message:
Cancel